EPOUT3=NoData, EPOUT5=NoData, EPIN2=NoData, EPOUT8=NoData, EPOUT6=NoData, EPOUT0=NoData, EPOUT4=NoData, EPIN1=NoData, EPOUT7=NoData, EPOUT1=NoData, EPIN7=NoData, EPIN5=NoData, EPOUT2=NoData, EPIN8=NoData, EPIN3=NoData, EPIN0=NoData, EPIN6=NoData, EPIN4=NoData
Provides information on which endpoint’s EasyDMA registers have been captured
EPIN0 | Captured state of endpoint’s EasyDMA registers. Write ‘1’ to clear. 0 (NoData): EasyDMA registers have not been captured for this endpoint 1 (DataDone): EasyDMA registers have been captured for this endpoint |
EPIN1 | Captured state of endpoint’s EasyDMA registers. Write ‘1’ to clear. 0 (NoData): EasyDMA registers have not been captured for this endpoint 1 (DataDone): EasyDMA registers have been captured for this endpoint |
EPIN2 | Captured state of endpoint’s EasyDMA registers. Write ‘1’ to clear. 0 (NoData): EasyDMA registers have not been captured for this endpoint 1 (DataDone): EasyDMA registers have been captured for this endpoint |
EPIN3 | Captured state of endpoint’s EasyDMA registers. Write ‘1’ to clear. 0 (NoData): EasyDMA registers have not been captured for this endpoint 1 (DataDone): EasyDMA registers have been captured for this endpoint |
EPIN4 | Captured state of endpoint’s EasyDMA registers. Write ‘1’ to clear. 0 (NoData): EasyDMA registers have not been captured for this endpoint 1 (DataDone): EasyDMA registers have been captured for this endpoint |
EPIN5 | Captured state of endpoint’s EasyDMA registers. Write ‘1’ to clear. 0 (NoData): EasyDMA registers have not been captured for this endpoint 1 (DataDone): EasyDMA registers have been captured for this endpoint |
EPIN6 | Captured state of endpoint’s EasyDMA registers. Write ‘1’ to clear. 0 (NoData): EasyDMA registers have not been captured for this endpoint 1 (DataDone): EasyDMA registers have been captured for this endpoint |
EPIN7 | Captured state of endpoint’s EasyDMA registers. Write ‘1’ to clear. 0 (NoData): EasyDMA registers have not been captured for this endpoint 1 (DataDone): EasyDMA registers have been captured for this endpoint |
EPIN8 | Captured state of endpoint’s EasyDMA registers. Write ‘1’ to clear. 0 (NoData): EasyDMA registers have not been captured for this endpoint 1 (DataDone): EasyDMA registers have been captured for this endpoint |
EPOUT0 | Captured state of endpoint’s EasyDMA registers. Write ‘1’ to clear. 0 (NoData): EasyDMA registers have not been captured for this endpoint 1 (DataDone): EasyDMA registers have been captured for this endpoint |
EPOUT1 | Captured state of endpoint’s EasyDMA registers. Write ‘1’ to clear. 0 (NoData): EasyDMA registers have not been captured for this endpoint 1 (DataDone): EasyDMA registers have been captured for this endpoint |
EPOUT2 | Captured state of endpoint’s EasyDMA registers. Write ‘1’ to clear. 0 (NoData): EasyDMA registers have not been captured for this endpoint 1 (DataDone): EasyDMA registers have been captured for this endpoint |
EPOUT3 | Captured state of endpoint’s EasyDMA registers. Write ‘1’ to clear. 0 (NoData): EasyDMA registers have not been captured for this endpoint 1 (DataDone): EasyDMA registers have been captured for this endpoint |
EPOUT4 | Captured state of endpoint’s EasyDMA registers. Write ‘1’ to clear. 0 (NoData): EasyDMA registers have not been captured for this endpoint 1 (DataDone): EasyDMA registers have been captured for this endpoint |
EPOUT5 | Captured state of endpoint’s EasyDMA registers. Write ‘1’ to clear. 0 (NoData): EasyDMA registers have not been captured for this endpoint 1 (DataDone): EasyDMA registers have been captured for this endpoint |
EPOUT6 | Captured state of endpoint’s EasyDMA registers. Write ‘1’ to clear. 0 (NoData): EasyDMA registers have not been captured for this endpoint 1 (DataDone): EasyDMA registers have been captured for this endpoint |
EPOUT7 | Captured state of endpoint’s EasyDMA registers. Write ‘1’ to clear. 0 (NoData): EasyDMA registers have not been captured for this endpoint 1 (DataDone): EasyDMA registers have been captured for this endpoint |
EPOUT8 | Captured state of endpoint’s EasyDMA registers. Write ‘1’ to clear. 0 (NoData): EasyDMA registers have not been captured for this endpoint 1 (DataDone): EasyDMA registers have been captured for this endpoint |